Drive Motor Forklift - MCC's or Motor Control Centersare an assembly of one section or more which include a common power bus. These have been used in the automobile industry ever since the 1950's, in view of the fact that they were made use of a large number of electric motors. These days, they are utilized in a variety of commercial and industrial applications.
Motor control centers are a modern method in factory assembly for some motor starters. This equipment could include metering, variable frequency drives and programmable controllers. The MCC's are usually found in the electrical service entrance for a building. Motor control centers often are utilized for low voltage, 3-phase alternating current motors that vary from 230 volts to 600 volts. Medium voltage motor control centers are intended for large motors which vary from 2300V to 15000 V. These units make use of vacuum contractors for switching with separate compartments so as to attain power switching and control.
Within factory locations and area which have corrosive or dusty processing, the MCC can be installed in climate controlled separated locations. Typically the MCC will be positioned on the factory floor close to the machines it is controlling.
For plug-in mounting of individual motor controls, A motor control center has one or more vertical metal cabinet sections with power bus. So as to complete testing or maintenance, very large controllers can be bolted into place, whereas smaller controllers may be unplugged from the cabinet. Every motor controller has a contractor or a solid state motor controller, overload relays In order to protect the motor, circuit breaker or fuses to supply short-circuit protection as well as a disconnecting switch in order to isolate the motor circuit. Separate connectors enable 3-phase power to be able to enter the controller. The motor is wired to terminals located in the controller. Motor control centers offer wire ways for field control and power cables.
Every motor controller in a motor control center could be specified with different choices. These options include: pilot lamps, separate control transformers, extra control terminal blocks, control switches, as well as various types of bi-metal and solid-state overload protection relays. They likewise have various classes of types of circuit breakers and power fuses.
There are many options regarding delivery of MCC's to the customer. They can be delivered as an engineered assembly with interlocking wiring to a central control terminal panel board or programmable controller together with internal control. On the other hand, they can be supplied prepared for the customer to connect all field wiring.
MCC's generally sit on floors which are required to have a fire-resistance rating. Fire stops could be necessary for cables which penetrate fire-rated walls and floors.
Click to Download the pdf